    DOG-208FA 130C

    DISSOLVED OXYGEN SENSOR

    DOG-208FA is high technology and high temprature dissolved oxygen electrode, which is specially designed to be resistant to 130 degrees steam sterilization, the pressure auto-balance high temperature dissolved oxygen electrode, for liquids or gases dissolved oxygen measurement, the electrode is most suitable for small microbial culture reactor dissolved oxygen levels on line. Can also be used for pharmaceutical,biotech,beer,Fermentation,sterilization,autoclaving,CIP etc

    TECHNICAL SPECIFICATIONS

    Model

    DOG-208FA

    Parameter measurement

    Dissolved oxyge,Temperature

    Measure range

    Dissolved oxygen:(0~20.0)mg/L,0~100ug/L

    Temperature:0~130.0℃

    Accuracy

    Dissolved oxygen: ±0.1ppb

    Material

    SS316L

    Permeable membrane

    Fluorine plastic, silicone, stainless steel wire mesh composite membrane.

    Cathode

    Platinum wire

    Anode

    Silver

    Temperature compensation

    PT1000

    The response current in the air

    About 60nA

    The response current in a nitrogen atmosphere

    Less than one percent response current of response in air

    Electrode response time

    About 60 seconds (up 95% response)

    Electrode Response StabilityA constant oxygen partial pressure at a constant temperature environment, response current drift less than 3% per week
    Liquid mixing flow to the electrode response3% or less (in water at room temperature)
    Electrode Response Temperature Coefficient3% (greenhouse)
    Electrode diameter12 mm, 25 mm optional
    Electrode insertion length120,225,325mm

    MAIN FEATURES

    130C Dissolved Oxygen Sensor DOG-208FA 8
    BOQU Instrument found the firstly high temperature labotary in China
    130C Dissolved Oxygen Sensor DOG-208FA 9
    DOG-208FA can directly replace METTLER TOLEDO and Hamilton high temperature dissolved oxygen sensor
    130C Dissolved Oxygen Sensor DOG-208FA 10
    High temperature dissolved oxygen electrode by Polarographic Principle
    130C Dissolved Oxygen Sensor DOG-208FA 11
    With imported breathable membrane heads,good work for pharmacy & biotech process control
    130C Dissolved Oxygen Sensor DOG-208FA 12
    Endure high temperature, No deformation characteristics
    130C Dissolved Oxygen Sensor DOG-208FA 13
    Steel gauze electrode membrane and silicone rubber
    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2025 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect