    BQJ104 DIGITAL

    PRESSURE CONTROLLER

    Description

    This is an intelligent digital displayed product for pressure testing and controlling. It integrates functions of measuring,display,output and control all in one.It has a complete electronic structure. Oil-filled piezo-restive pressure sensor with diaphragm is applied in the front part. The output is processed by high-precision & low-temperature drift amplifier,then transformed by high accuracy

    A/D converter into digital signal that could be processed by MPU(Micro Processor Unit).

    The processed signals control two switches then to test&control the pressure.

    With flexible application,simple handling,easy debugging and high reliability,this product is widely used applied to test & control the pressure of fluid medium in many industries including areas of hydroelectricity,city water,oil,chemical,machinery hydraulic system etc.

    Notice

    1. To be stored and used in ambient temperature -20-70℃ and relative humility 0-80%,
    2. Connecting thread should be concentric and stable with the pipe system,
    3. When disassemble this product,please do not press it in its body

    SPECIFICATIONS

    Pressure range

    -0.1~0~100Mpa

    Accuracy

    0.5%F.S.

    Over load

    200%

    Pressure type

    Gauge/absolute

    Liability

    ≤0.1% /year

    Power

    24VDC/220VAC

    Display

    0.56" LED

    Display range

    -1999~9999

    Response time

    <30ms

    Ambient temperature

    -20℃~70℃

    Relative humidity

    ≤80%

    Wetted part

    SS304

    INSTALLATION

    1. Mechanical connection

    It can be directly mounted in the hydraulic pipe by the connecting thread,M20*1.5. In critical application,such as server vibration or shock,soft hose is recommended to use.

    2. Electrical connection

    To avoid electromagnetic interference,please know

    A.The cable system should be as short as possible

    B.To use shielded wire

    C.To keep way from any interference resources,for example,electric appliances and devices.If installed by soft hose,its body should be grounded independently.

    Intelligent Digital Pressure Controller BQJ104 6
    Intelligent Digital Pressure Controller BQJ104 7
    Intelligent Digital Pressure Controller BQJ104 8

    SETTING

    AL1H: Switch connection point for switch 1(when pressure reaches this value,indicator on)

    AL1F: Switch connection point for switch 1(when pressure reaches this value,indicator off)

    AL2H: Switch connection point for switch 2(when pressure reaches this value,indicator on)

    AL2F: Switch connection point for switch 2(when pressure reaches this value,indicator off)

    FILT:Filter coefficient. To avoid digit display from fluctuating which is caused by pressure change.after 3-10seconds,it can be set END then save then exit.The bigger the filter coefficient is,

    The more stable it is,but the more hysteric.

    NOTE

    Intelligent Digital Pressure Controller BQJ104 9
    Switching points are determined by the configuration of the present connection and disconnection value.
    Intelligent Digital Pressure Controller BQJ104 10
    When connection value is higher than disconnection value,it is called upper-limit alarm output(normally open status);
    Intelligent Digital Pressure Controller BQJ104 11
    When connection value is lower than disconnection value,it is called lower-limit alarm output(normally close status);
    Intelligent Digital Pressure Controller BQJ104 12
    The deviation between connection and disconnection value is the return difference for the switch point.
    Intelligent Digital Pressure Controller BQJ104 13
    Intelligent Digital Pressure Controller BQJ104 14
    Intelligent Digital Pressure Controller BQJ104 15

    EXAMPLE

    (How to finish the settings as following)

    Set switch point 1 at upper-limit alarm output(normally open status),connect at 4Mpa and disconnection when lower than 3.95Mpa,response delay is 3 seconds

    Set switch point 2 at lower-limit alarm output(normally close status),connect at 10Mpa and disconnection when lower than 9.95Mpa,response delay is 10 seconds

    Enter the menu:Set

    AL1H=4.00 AL1F=3.95

    AL2H=9.95 AL2F=10.00

    ● Press “SET”

    ● “LOCK”sign(remind you to key in password,0001)

    ● Press ▲ or ▼ to key in the password

    ● Press “SET” to confirm

    ● Press ▲ or ▼as page up or page down to select

    (AL1H, AL1F, AL2H, AL2F, END)

    ● Press “SET” to enter selection menu

    ● Press ▲or ▼ to alter the settings

    ● Press “SET” to confirm,or press ▲or▼to enter other menus for other settings

    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2025 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect