    COD-1C LABORATORY

    COD ANALYZER

    Chemical Oxygen Demand (COD or CODcr) refers to the amount of oxidant consumed caused by oxidation of reducing substances in water under specific condition, recorded as the amount of oxygen consumption counted by “mg/L”. It indicates the water pollution degree by these reducing substances, including organic matter, nitrite, ferrous salt and sulfide, etc. There is a small amount of inorganic reducing substances but a large amount of organic matters. So, COD can be used as a comprehensive index of relative content of organic matters.

    Principle

    COD: Sample is sealed and digested in strong acid solution with exclusive oxidant which contains potassium dichromate, and then under special composite catalyst, digestion temperature is 165℃, last for 15 min. Hexavalent chromium in Potassium dichromate is reduced to trivalent chromium by organic matter in water. The amounts of trivalent chromium are measured at 420nm and 610nm respectively, finally, base on the amounts of trivalent chromium, calculate the consumption of oxygen concentration.

    TECHNICAL PARAMETERS

    Product

    COD-1C LABORATORY COD ANALYZER

    Measuring range

    5~2000mg/L (three ranges: CODL 5~200 mg/L, CODM 200~1000 mg/L and CODH 1000~2000 mg/L),(over range can be diluted)

    Acurracy

    COD:  5~100 mg/L, Absolute Error (AE)≤±8mg/L,100~2000mg/L;Relative Error (RE)≤±8%

    Display

    Read the value BOD5 from dividing rule of pressure gauge(mg/L)

    Anti-Chlorine Interference

    ≤2000mg/L

    Power Consumption

    300W

    Digestion Temp

    165℃±1.5℃

    Digestion time

    15 min

    Optical Systems (wavelength)

    420 nm and 610 nm

    Host dimension

    240mm×206mm×170mm 

    Digestion tank

    240mm×107mm×170mm    

    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2025 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect