    DOS-118A ppb level portable dissolved oxygen meter is electrochemical analyzer of polarographic measuring principle. Measurement of oxygen in the gas, can also measure the dissolved oxygen in aqueous solution.

    The oxygen concentration in the gas (unit%) used for the measurement of grain, fruit, herbs warehouses, tunnel, air defense and naval vessels, also used to measure the pulmonary function of the medicine, power station, metallurgy, chemical and other boiler combustion process oxygen concentration in the gas phase.

    Dissolved oxygen (unit mg/L) is dissolved in water or liquid molecular oxygen, its content is an important indicator of water quality merits. The measurement of dissolved oxygen is the indispensable monitoring project of power generation, boiler, aquaculture, water protection, water supply, sewage treatment and other departments.

    TECHNICAL INDEXES

    ProductDOS-118A PORTABLE PURE WATER DISSOLVED OXYGEN METER (ppb level)

    Measuring range

    Resolution: 0.0001mg/L
    Accuracy: 0.001 mg/L (automatic switch)

    Indication error

    ± 0.001mg/L

    Repeatability

    ≤0.001mg/L

    Response time

    Not more than 30s (90%, 25 ℃)

    Zero values (error)

    (.0000-.1999) mg/L ≤0.001 mg/L

    Working conditions

    a) Ambient temperature: 5-35℃

    b) Relative humidity: ≤85%RH.

    c) Power supply: DC3V

    d) Measured medium temperature: 5-40℃

    e) It should be no electromagnetic interference influence the normal operation of the instrument

    f) Atmospheric pressure: 86-106 kPa

    g)Power supply environment and good air circulation, without affecting the accuracy of detection of interference gas.

    h) Power consumption: two No. 5 batteries run continuously for 365 days. (UPS)

    I) Maintenance cost: free maintenance

    Power supply voltage changes effect amount

    Instrument indication error 1/5.

    Ambient temperature change effect amount

    Instrument indication error 2/3.

    Oxygen electrode life

    More than one year.

    Power dissipation

    <2mW

    Size

    25 x 68 x 133mm

    Weight

    230g

    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2025 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect